Angio cpet - single set

Modern ergometer with multifunctional applications

The Angio cpet is an ergometer that can be used for both arm and supine ergometry. Its compact design makes it universally applicable for ergometric studies in those sectors in which standard ergometry cannot be used. The Angio operates independent of pedaling speed in the range of 7 - 1000 watt. The Angio cpet is standard supplied with a communication module and can therefor be easily controlled by all known stress ECG and pulmonary devices in the world. The workload, rpm and time can be readout from the 3,5" colour display. The ergometer is supplied with standard pedals.

Highlights

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2003, ISO 13485:2008 and FDA 510K certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Easy to operate

For Lode products this means:
- easy to connect
- easy to move around
- easy user interface

Reliable and reproducible stress tests

The experience of professionals who calibrate many ergometers shows that the Lode ergometers are the most reliable across the complete workload and rpm range and still within specifications even after many years of intensive use.

Multifunctional

The ergometer can be used in various ergometry settings, enabling a multifunctional deployment.

Additional features with PCU

Besides the possibility to program 24 protocols easily, this control unit offers the following features:
- better monitoring because of the additional and larger display
- a perfect combination with BPM
- possibility to measure SpO2

Features

Accurate over a long period of time

The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.

Extreme low start-up load

The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.

Small adjustment steps

The workload of the Lode ergometers is adjustable in steps of only 1 watt. Depending on your wishes, the test operator or the test subject can adjust the workload. The steps of 1 watt are possible in the manual mode as well as within protocols.

LEM compatible

This product can be used with Lode Ergometry Manager (LEM) software to manage data and to apply specific protocols when a Communication card or Network card is present

LCRM compatible

This product can be used with Lode Cardiac Rehabilitation Manager software (LCRM)
Versatile controls

Additional features with PCU

Besides the possibility to program 24 protocols easily, this control unit offers the following features:
- better monitoring because of the additional and larger display
- a perfect combination with BPM
- possibility to measure SpO2

Versatile Interfacing

Various interface protocols guarantee perfect communication with all commonly known stress ECG and spirometry equipment

Specifications

Minimum load 7 W the minimum load the ergometer can provide
Maximum peak load 1000 W the maximum load the ergometer can provide for a short period of time
Minimum load increments 1 W the smallest steps with which the load can be added
Maximum continuous load 750 W the maximum power the ergometer can deliver continuous
Hyperbolic workload control
control of workload in hyperbolic way
Linear workload control
control ergometer in a linear way
Fixed torque workload control
control ergometer in a fixed torque way
Maximum rpm independent constant load 150 rpm rpm as to which constant load can be applied
Minimum rpm independent constant load 30 rpm rpm as from which constant load can be applied
Optional heart rate controlled workload
control the device optionally through a set heartrate
Electromagnetic "eddy current" braking system
system that very accurately applies a brake to the ergometer
Workload accuracy from 7 to 100 W 3 W accuracy of the ergometer between 7 and 100 Watt
Workload accuracy from 100 to 500 W 3 % accuracy of the ergometer between 100 and 500 Watt
Workload accuracy from 500 to 1000 W 5 % accuracy of the ergometer between 500 and 1000 Watt
Readout Distance
Readout the distance on control unit
Readout RPM
Readout the actual rpm on control unit
Readout Heartrate
Readout the actual heartarte on control unit
Readout target HR
Readout target heartarte on control unit (only possible with HR option)
Readout Energy
Readout the energy on control unit
Readout Torque
Readout torque on control unit
Readout Time
Readout time on control unit
Readout Power
Readout the actual power on control unit
Set Display
Choosing parameters to be shown on the display during the stress test
Set Resistance
Possibility to define a specific resistance for each test subject
Set P-Slope
Possibility to set the load regulation resistance
Set Mode
Possibility to define parameters to be adjusted during the stress test
Manual operation mode
Operate manually
Preset protocol operation mode
Operate via preset protocols
External control unit
a control unit is connected with a cable to the ergometer
Selfdesigned protocol operation mode
operate via selfdesigned protocols
Product weight 26 kg 57.3 lbs the weight of the product
V AC 100-240 V voltage in Volt
Phases 1 phases
Frequency 50/60 Hz frequency in Herz
Power consumption 160 W power consumption in Watt
Power cord IEC 60320 C13 with CEE 7/7 plug
European power cord and connector standard supplied with product
Power cord NEMA
NEMA power cord and connector
IEC 60601-1:2012
the product is IEC 60601-1 edition 3.1 compliant
ISO 13485:2003 compliant
Lode fulfils ISO 13485:2003 requirements
ISO 9001:2008 compliant
Lode fulfills ISO 9001: 2008 requirements
CTüVus according to NRTL - pending
cTüVus certification - pending
CB according to IECEE CB - pending
CB certification pending
CE class Im according to MDD93/42/EEC - pending
CE certification pending
Maximum operational temperature 35 °C maximum temperature at which the device will work within specification
Minimum operational temperature 14 °C minimum temperature at which the device will work within specification
Maximum operational air pressure 106 kPa maximum air pressure as from which the product will be operating within specification
Minimum operational air pressure 80 kPa minimum airpressure as from which the product will be operating within specification
Maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
Minimum operational non-condensing humidity 30 % minimum non-condensing humidity at which the product will operate within specification
Maximum storage & transport temperature 60 °C maximum temperature the product may be stored or transported at
Minimum storage & transport temperature -20 °C minimum temperature the product may be stored and transported at
Maximum storage & transport air pressure 106 kPa maximum air pressure the product may be stored and transported at
Minimum air pressure storage & transport 50 kPa minimum air pressure the product may be stored or transported at
Max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
Min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at
*Specifications are subject to change without notice.

Science

FAQ

Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.
The load will only be returned when the pedalling speed is 30 RPM or more. For technical details see the Lode RS232 protocol
Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition.
Not sure what this means? Contact us and we will help you to get the right converter.

Part number

  • 967900

Certificates

ISO 13485:2003 Certificate

Demo Software

Simulator of Control Unit 945834 as used with Corival
Simulator of Programmable Control Unit 945835 as used with Corival

Dimension pictures

Dimensions of the Angio (3.5 inch screen)

LEM Demo Software

955900 LEM 10.6.0 Demo software

Manuals

M967900 - Manual Angio cpet single set English

Brochures

Brochure Angio cpet - single set English
pdf
Brochure Cardio Pulmonary English
pdf
Brochure Angio cpet - single set German
pdf
Brochure Cardio Pulmonary German
pdf

Posters

Poster Angio cpet - single set English
Poster Cardio Pulmonary English
Poster Angio cpet - single set German
Poster Cardio Pulmonary German

Service

Part number

  • 967900

Interfacing protocols

AEI Technologies
BTL
Cardiolex
CareFusion
Carewell
Cognimed
Cortex
Cosmed
Custo Med
Delmar Reynolds
Edan Instruments Inc.
Enverdis GmbH
ET Medical
GE Healthcare
Korr Medical Technologies Inc
Labtech
Med-tronik
Medical Graphics
Medset
Mesa Medizintechnik
Mortara
Neurosoft
Nihon Kohden
Norav
nSpire Health
Parvomedics
Philips Medical
Progetti
Pulse Biomedical, Inc.
Quinton
Schiller
Seiva
Welch Allyn
1350K
1500 K / 1550K - Cardiofax V
600 USB system
9320K
AT-10
AT-104 PC
AT-110
AT10 Plus
BreezeSuite Software
BTL-08 ECG
Cardiax PC-EKG
Cardio Coach Monitor
Cardio Collect 12
Cardiologic Explorer 12C Ergo
CardioPerfect
Cardiosoft
Cardiosoft + Corina
Cardiosoft MAC 1200 ST
CS200
Cubestress
Custo Diagnostic Stress ECG
EC Sense
EC12 R/S
Edan EC-12 EXPRESS
Edan ST-1212 STRESS ECG
Ergolog
Flashlight
GE Case
GE Case 8000
GE Case Basic
GE Case Performance
GE Case Premium
GE Case Value
K5
Lactware Software
MasterScreen® ECG / Viasys Oxycon Pro
Metasoft
MOXUS Modular Metabolic System
MyStress system
PC ECG 1200
Poly Spectrum
Q-Stress
QRS-card
Quark CPET
Quark PFT
Quark RMR
StressVue
T12
TM Cardio 1000/2000
TrueOne
Vyntus CPX / SentrySuite ≥ 2.17 software
X-scribe