Blood Pressure with ECG trigger for bicycle ergometer

with ECG trigger

This option enables accurate and reliable automatic blood pressure measurement during cardiac rehabilitation, not disturbed by motion artifacts. The integrated BPM option is supplied as part of a complete cardiac rehabilitation setting using LCRM. This means that the BP measurement can be started and saved from the LCRM software. BP measurementis done according to the Korotkoff method


Note: for the blood pressure measurement, a trigger is needed

Highlights

Easy to operate

For Lode products this means:
- easy to connect
- easy to move around
- easy user interface

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Compatible with ECG and pulmonary devices

The treadmill can be controlled by all external stress test ECG and ergospirometry devices through the RS232 or USB port. This is possible because besides the programmed Lode protocol, all known communication protocols are programmed as well.

Features

Versatile Interfacing

Various interface protocols guarantee perfect communication with all commonly known stress ECG and spirometry equipment

Original Accessory

Accessory designed and manufactured according to the Lode company quality standards

Specifications

Accuracy BPM <300 mmHg 3 mmHg Accuracy of the BPM module between 0-300 mmHg
Minimum systolic measurement 50 mmHg Minimum BPM Measurement Range
Maximum systolic measurement 250 mmHg Maximum BPM Measurement Range
Minimum diastolic measurement 20 mmHg Minimum BPM Measurement Range
Maximum diastolic measurement 150 mmHg Maximum BPM Measurement Range
TTL input 3-5 V TTL input required for BPM
Pulse length 45 - 95 ms Pulse length required for BPM
Maximum delay between RS-peak and pulse 40 ms Required for BPM
Variances in delay time (jitter) <5 ms Required for BPM
*Specifications are subject to change without notice.

FAQ

The K-sound Microphone can be cleaned using a mild disinfectant wipe (e.g. Sani-Cloth®) and letting the microphone line dry.
Presence of atrial or ventricular fibrillation, arrhythmias, pacemakers, etc. may interfere with the normal functionality of the BP monitor.

Specifications Blood Pressure Measurement Measurement: Auscultatory, using R-wave gating and k-sound analysis, during all static and active phases of stress testing. Systolic pressures correlate to a K-1 Korotkoff sound. Diastolic pressures correlate to K-5 Korotkoff sound. The device is designed to function in the presence of a normal ECG sinus rhythm. There are some physical conditions (i.e. Bundle Branch Block, Arrhythmias, Arial Fibrillation, Ventricular Fibrillation, Pacemakers, etc.) that may limit the ability of BP Monitor to obtain an accurate reading.

Notes on Blood Pressure Data Any blood pressure reading can be affected by the measurement site, the position of the patient, exercise, or the patient’s physiologic condition. Environmental or operational factors which can affect the performance of the device and/or its blood pressure reading are pacemakers and common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, pre-eclampsia, renal diseases, patient motion, trembling, and shivering.
Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!

Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.
When the automatic Blood Pressure option is available on the Lode ergometer, this module is compatible with LCRM. You can program the blood pressure interval in the exercise protocols.

Part number

  • 945828

Certificates

Mdoc_MDR

Manuals

M945828 - manual Blood Pressure Measurement for ergometer Bulgarian
M945828 - manual Blood Pressure Measurement for ergometer English
M945828 - manual Blood Pressure Measurement for ergometer Dutch

Brochures

Brochure Blood Pressure with ECG trigger for bicycle ergometer English
pdf
Brochure Rehabilitation English
pdf
Brochure Blood Pressure with ECG trigger for bicycle ergometer German
pdf
Brochure Rehabilitation German
pdf
Brochure Blood Pressure with ECG trigger for bicycle ergometer Spanish
pdf
Brochure Rehabilitation Spanish
pdf

Posters

Poster Rehabilitation English
Poster Rehabilitation German
Poster Rehabilitation Spanish

Service

Part number

  • 945828