Lode Cardiac Rehab Manager

Turn-key Solution for Cardiac Rehabilitation

Lode offers a turn-key solution for cardiac rehabilitation. The complete solution consists of our intuitive and user-friendly LCRM software, a very compact wearable ECG streamer and is completed with our reliable Lode rehab ergometers.


 


The LCRM software (#950902) is unique and control the Lode rehab devices. It helps the test operator to prepare cardiac rehabilitation sessions by the possibility to predefine protocols and test groups. The software also documents all relevant data (e.g. ECG, BPM, SpO2, Speed, Inclination, RPM, Load, etc) for later analysis and provides individual reports and continuous ECG control. The test operator can rely on the quality of the software and thus focus on the patients. The extensive patient database can work as a stand-alone database or linked to a SQL server. Of course HL7 connection to the Hospital Information System (HIS) is possible.


 


The compact 2-channel ECG streamer (#950920) is wearable and wireless. This makes it possible for the test subject to move around the ergometer and perform all kind of exercises while the ECG data are still monitored. The batteries of multiple ECG streamers can be charged using a USB cord or simultaneously in a docking station.


 


Each Cardiac Rehabilitation Solution is custom made, based on the requirements of the user. You can use part number #950902 for ordering the LCRM software for a setting with 2 stress test devices. For each additional device, you can order an additional license (#950906). For a complete setup, please check the accessories and related products or contact your local Lode distributor. 

Interconnectivity between Lode products
Analyzing the LCRM training data
Documentation
Complete setup turn key delivered

Highlights

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2003, ISO 13485:2008 and FDA 510K certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Complete setup

The modular structure of the software combined with the accurate and reliable Lode ergometers offers a complete and modern ergometry setting.

Everything in control

Easy set up of Subject data
Create protocols quickly and efficiently
Overview of progress during test

Multifunctional software for all Lode ergometers

The software can be used for all Lode ergometers and treadmills, including their options like bloodpressure, heart rate, SpO2 etc.
Load as well as bloodpressure triggers can be set remotely.

Easy to install

- Simple step by step installer
- Easy setup of ergometers
- Easy setup of subjects

Features

Turn key delivery

The complete setup is delivered turn key, so that you can start using it immediately.

Patient Database

An extensive patient database is available, which can work as a stand alone database or linked to a SQL server. HL7 connection to the Hospital Information System (HIS) is possible.

Data dashboard available

Various ergometry data is made visible, enabling the operator to simultaneously visualize ergometric parameters during the test and to control or quickly intervene when necessary.
Monitor

Monitor during the test

The visualisations on the monitor can be selected by the operator to define a clear and usefull visual overview during the exercise test. The lay-outs for different purposes can be saved by the operator

Customizable view

The operator can define which data is displayed on the screen. Data not visualized during the test is recorded and can be analyzed at any time.

Add remarks

Remarks can be added and modified before, after and
during the test
Clear results

Multiple analysis modes

Easy access to Analysis menu. Creating individual comparisons with an overview of the performed tests.

Borg RPE scale integrated

Ratings of Perceived Exertion: an aid to help estimate the amount of exertion, the load and fatigue on a scale of 6 to 20.

Specifications

60 Hertz Filter
60 Herz ECG Filter
50 Hertz Filter
50 Hertz ECG Filter
Two channel ECG monitoring
ECG monitoring with 4 leads, two channel
Alarm Heart Rate
Alarm Heart Rate
Alarm Blood Pressure
Alarm Blood Pressure
Audio Alarm
Audio Alarm
Remote Battery Indication
Remote Battery Indication
Versatile database connection
Versatile database connection
Customized Screenviews
Customized Screenviews
Customized Reports
Customized Reports
Personalized Color Settings
Personalized Color Settings
Software available in English
Software available in English
Software available in German
Software available in German
Software available in Dutch
Software available in Dutch
Software available in French
Software available in French
Software available in Russian
Software available in Russian
Software available in Polish
Software available in Polish
Software available in Japanese
Software available in Japanese
RS232 connection to Lode ergometers
RS232 connection to Lode ergometers
USB connection to Lode treadmills
USB connection to Lode treadmills
Bluetooth available
connectivity through Bluetooth available
Max. wireless slots per monitor 8 the maximum number of test subject that can be connected
Intel Core based processor 2.4 GHz clock frequency
Monitor 1920 x 1080 pixels Resolution
Internal RAM 4000 MB minimum PC internal memory
Minimum Free Hard Disk space 20 GB software and storage size requirement
CD Rom drive required
installation medium input
Number of free USB ports 1 for connection purposes
Mouse
for input
Keyboard
for input
HL7 compatible
HL7 compatible
Compatible with MS SQL Server
Connection with MS SQL Server
Database SQL Compact Database used
Database limit when used as local database 4 GB Database limit
Microsoft Windows 10
compatible with Microsoft Windows 10
Microsoft Windows 8
compatible with Microsoft Windows 8
Microsoft Windows 7
compatible with Microsoft Windows 7
PC included
the software is preinstalled on a PC that is included
PC software included
software needed for operation included
Windows 7 installed
operating system preinstalled on PC
Keyboard and mouse included
Input devices are included with the PC
LCD screen included
large display for monitoring patients
All cables included
cables for installing the complete setup are included
*Specifications are subject to change without notice.

Science

FAQ

Yes, you can find interface sheets for most common devices on the website at the "service" tab of this website. If your device is not present you can ask us to support you. In most cases we can quickly provide you with a solution.
Yes the Valiant Treadmill can be controlled by the LEM and the modules Export and Multi Control. The treadmill is supplied with a RS232 port and can be controlled by a seperate communicationport
es the Valiant Treadmill can be controlled by LCRM. The treadmill is supplied with a RS232 port and can be controlled by a seperate com port.
Yes the SpO2 results are visible during the rehab session.
For turning off the ECG module - Hold the power button for a few seconds until the LED turns an amber color. Continue holding the button until the LED blinks and goes amber again. On the second amber flash, release the power button. This will power down the device.
Yes! It is very easy to create a comfortable rehab setting with Lode rehab products by looping the ergometers:

The first Lode rehab ergometer can be connected to the PC with LCRM with a Lode proprietary network to PC cable (#930930).
The second product up till the last product can be connected to the previous one, a bus network configuration.

The last product always needs a termination plug to avoid interference and loss of data. All Lode rehab products come standard with such a termination plug.

Benefits
- Flawless data connection
- High bandwidth
- No interference of COM ports
- Looping
- Full access of all data in the product to LCRM

Part number

  • 950902

LCRM Demo Software

950900 LCRM 2.12.1 demo software

Manuals

M950900 LCRM Manual ENG
M950900 LCRM Manual Dutch

Brochures

Brochure Lode Cardiac Rehab Manager English
pdf
Brochure Rehabilitation English
pdf
Brochure Lode Cardiac Rehab Manager German
pdf
Brochure Rehabilitation German
pdf

Posters

Poster Lode Cardiac Rehab Manager English
Poster Rehabilitation English
Poster Lode Cardiac Rehab Manager German
Poster Rehabilitation German

Service

Part number

  • 950902