Lode ECG Streamer

Compact wireless ECG registration

The Lode ECG streamer has 4 leadwires that will deliver 2 channels of ECG: Lead I and Lead II. The streamer can be supplied with an optional custom pack (#950824) for triggering the TTL pulse (needed for blood pressure measurement).  


The ECG streamer is extremely light weight and small. The batteries are rechargeable and can be used for approximately 8 hours. During a cardiac rehab training,  test subjects can press the marker button themselves.  The streamer is supplied with disposable electrodes to create more flexibility when moving from one exercise device to the other.

Highlights

Easy to install

- Simple step by step installer
- Easy setup of ergometers
- Easy setup of subjects

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Complete Ergometry setting

The modular structure of the software combined with the accurate and reliable Lode ergometers offers a complete and modern ergometry setting.

Features

Original Accessory

Accessory designed and manufactured according to the Lode company quality standards

Specifications

Sampling resolution 16 bit resolution of sampling
Sampling frequency 250 Hz frequency of sampling
Two channel ECG monitoring
ECG monitoring with 4 leads, two channel
CMRR ECG sensor >100 common-mode rejection ratio is a metric used to quantify the ability of the device to reject common-mode signals
Maximum sample frequency event button 1 Hz push button to track event
LED Indication
Status indication with LED
Trigger for blood pressure measurement Opt. Trigger signal to start a blood pressure measurement
Remote Battery Indication
Remote Battery Indication
Theoretical maximum range 20 m Maximum range bluetooth signal (depending strongly on the environment)
Bluetooth bandwith 64 kbit/s Bluetooth bandwith
Bluetooth
Connectivity via bluetooth
LCRM
Can be controlled using the Lode Cardiac Rehab Manager Software
Product weight 7 gr Weight of the product
Product height (mm) 25 mm height of product in mm
Product length (mm) 94 mm length of the product in mm
Product width (mm) 36 mm width of the product in mm
Rechargeable LiPo battery
Equipped with a rechargeable LiPo battery
Autonomy 8 h maximum operating time with fully charged battery
Charging time battery 3 h Time to fully charge the battery
IEC 60601-1:2012
the product is IEC 60601-1 edition 3.1 compliant
IEC 60601-2-47:2015
The product is IEC 60601-2-47:2015 compliant
ISO 13485:2016 compliant
Lode fulfils ISO 13485:2016 requirements
ISO 9001:2015 compliant
Lode fulfills ISO 9001: 2015 requirements
Minimum operational temperature 10 °C minimum temperature at which the device will work within specification
Maximum operational temperature 45 °C maximum temperature at which the device will work within specification
Minimum operational non-condensing humidity 10 % minimum non-condensing humidity at which the product will operate within specification
Maximum operational non-condensing humidity 95 % maximum non-condensing humidity at which the product will operate within specification
Minimum storage & transport temperature 0 °C minimum temperature the product may be stored and transported at
Maximum storage & transport temperature 45 °C maximum temperature the product may be stored or transported at
Min. humidity storage & transport 95 % minimum non-condensing humidity that the product can be stored or transport at
Max. humidity storage & transport 10 % max. non-condensing humidity that the product can be stored or transported at
Waterresistant IP67 device can withstand water
Lanyard
Lanyard to wear the ECG device
Bluetooth dongle
Bluetooth dongle
All cables included
cables for installing the complete setup are included
*Specifications are subject to change without notice.

Science

FAQ

Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!

Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.

Part number

  • 950920

LCRM Demo Software

Installation Instruction LCRM Demosoftware
950902 LCRM 3.0.1 demo software

Manuals

M950920 - Manual Lode ECG Streamer English
M950920 - Manual Lode ECG Streamer Dutch

Brochures

Brochure Lode ECG Streamer English
pdf
Brochure Rehabilitation English
pdf
Brochure Lode ECG Streamer German
pdf
Brochure Rehabilitation German
pdf
Brochure Lode ECG Streamer Spanish
pdf
Brochure Rehabilitation Spanish
pdf

Posters

Poster Rehabilitation English
Poster Rehabilitation German
Poster Rehabilitation Spanish

Service

Part number

  • 950920