Lode Research Data Logger

Multiple sensors in a wearable device

The Lode Research Data Logger allows for a multitude of datalogging options. The 4Gb data storage can be allocated to various data streams that can be set within the special included application. Datastreams can be set up to max 1000 Hz for ECG and other relevant high frequencies for the other sensors:

2-lead ECG
XYZ acceleration up to 4g
Magnetoscope data
Gyroscope data
Environmental light conditions
User action event logging

The device is IP 68 waterproof when used with a cover cap.
Application areas are numerous. One can think of various sports logging applications, e.g in extreme (wet) circumstances, movement analysis etc.
The software allows for data upload in .csv format to your PC.

Highlights

Water resistance

The sensor is water resistant (IP68)

Flexibility in sample frequency

For all the type of sensors different sample frequencies can be chosen

Battery life

Battery life is around the 24 hours with all sensors on maximum sample frequency

Raw data

The export file contains raw data from all the sensors

Multiple sensors

The data logger contains several sensors which can be set individually

Features

Modern OS compatibility

- Windows Windows 7
- Microsoft Windows 8
- Microsoft Windows 10

USB connectivity

USB to connect to PC facilitates easy connectivity.

CSV file

Export file is a CSV file which easily can be used in:
- excel
- matlab
- python

Field measurements

The wireless sensor, together with the battery life and data storage capacity makes it possible to measure easily in the field

Specifications

Data storage capacity 4 GB how much data can be stored
Maximum sample frequency ECG 1000 Hz maximum sample frequency of the electrocardiography
Resolution ECG sensor 16 bit the conversion of an analog voltage to a digital value in a PC
CMRR ECG sensor >100 common-mode rejection ratio is a metric used to quantify the ability of the device to reject common-mode signals
Maximum sample frequency accelerometer 250 Hz maximum sample frequency of the accelerometer
Resolution accelerometer 12 bit the conversion of an analog voltage to a digital value in a PC
DC accuracy accelerometer 0.02 DC accuracy
Measurement range accelerometer ±4 g minimal and maximal measurement value accelerometer
Maximum sample frequency gyroscope 250 Hz maximum sample frequency of the gyroscope
Resolution gyroscope 16 bit the conversion of an analog voltage to a digital value in a PC
Measurement range gyroscope ±2000 °/s minimal and maximal measurement value gyroscope
Maximum sample frequency magnetometer 50 Hz maximum sample frequency of the magnetometer
Resolution magnetometer 16 bit the conversion of an analog voltage to a digital value in a PC
Measurement range magnetometer ±4800 µT minimal and maximal measurement value magnetometer
Maximum sample frequency light sensor 10 Hz maximum sample frequency of the light sensor
Resolution light sensor 16 bit the conversion of an analog voltage to a digital value in a PC
Measurement range light sensor 0.01-100k lumen minimal and maximum measurement value light sensor
Maximum sample frequency event button 10 Hz push button to track event
LDEM
Lode Data Extraction Manager
USB connector
connection via USB possible
Product height (mm) 25 mm height of product in mm
Product length (mm) 94 mm length of the product in mm
Product width (mm) 36 mm width of the product in mm
Product weight 0.04 kg 0.1 lbs the weight of the product
Autonomy 1440 min maximum operating time with fully charged battery
Maximum operational temperature 40 °C maximum temperature at which the device will work within specification
Minimum operational temperature 5 °C minimum temperature at which the device will work within specification
Maximum operational non-condensing humidity 95 % maximum non-condensing humidity at which the product will operate within specification
Minimum operational non-condensing humidity 25 % minimum non-condensing humidity at which the product will operate within specification
Maximum storage & transport temperature 45 °C maximum temperature the product may be stored or transported at
Minimum storage & transport temperature 0 °C minimum temperature the product may be stored and transported at
Max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
Min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at
Waterresistant IP68 device can withstand water
Microsoft Windows 10
compatible with Microsoft Windows 10
Microsoft Windows 8
compatible with Microsoft Windows 8
Microsoft Windows 7
compatible with Microsoft Windows 7
PC software included
software needed for operation included
All cables included
cables for installing the complete setup are included
*Specifications are subject to change without notice.

Part number

  • 950931

Manuals

M950931 - Manual Research Data Logger
M950931 - Manual Research Data Logger NL

Brochures

Brochure Lode Research Data Logger English
pdf
Brochure Rehabilitation English
pdf
Brochure Lode Research Data Logger German
pdf
Brochure Rehabilitation German
pdf

Posters

Poster Lode Research Data Logger English
Poster Rehabilitation English
Poster Lode Research Data Logger German
Poster Rehabilitation German

Service

Part number

  • 950931