Portable Calibrator Ultra 230V

Easy and efficient calibration of ergometers

The Calibrator Ultra is an easy to set up and very accurate portable calibration station. The calibration station is controlled by a PC or laptop. With this station it is possible to control or calibrate all existing ergometers accurately. The Lode Calibrator is mounted on the axis of the ergometer. This system is approved by an independent institute, and is used by calibration institutes all over the world since 1993. Calibrations can be done up to 1500 watt. Due to the possibilities you create when using a normal PC to calibrate the calibrator you can print a calibration report for your customer and/or create your own database of calibration data.
The Calibrator Ultra is a professional Calibration station, made by Lode, which helps you to professionalize your calibrations and make your service more efficient. 

Highlights

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2003, ISO 13485:2008 and FDA 510K certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Features

Extremely Accurate Calibration of Ergometers

Highly accurate calibration of ergometers is possible with this product
Professional tool

Professional Service Tool

Lode provides tools for service engineers of distributors that are completely dedicated to its products and purpose. Some can even be used for non-Lode calibration activities
Universal

Universal Calibration

This tool can be used for Calibration of Lode products as well as products of other manufacturers
Multiple connectors

Multiple ergometer axis connectors available

Various accessories are available to connect the calibrator to most available ergometers

USB connectivity

USB to connect to PC or ECG or ergospirometry products facilitates easy connectivity.

Specifications

Minimum rotational speed 25 rpm calibrator minimum rotations
Maximum rotational speed 180 rpm calibrator maximum rotations
Rotation direction clockwise
looking at the outgoing axis
Rotation direction anti-clockwise
looking at the outgoing axis
Maximum motor torque 100 Nm the maximum torque the motor can deliver
Maximum sensor torque 100 Nm the maximum torque the sensor can measure
Warming up time 5 min the time to bring the product on operational temperature
Approved power range (maximum) 1000 W power range for which use is approved
Approved power range (minimum) 0 W power range for which use is approved
Power range at maximum rpm (maximum) 1500 W operational power range
Power range at maximum rpm (minimum) 0 W operational power range
Crank adapter included
to connect crank to calibrator
Speed accuracy 0.25 % accuracy of speed
Power accuracy error > 100 W 1 % accuracy of power application
Power accuracy error up to 100W 1 W accuracy of power application
Torque resolution 0.05 Nm resolution of the torque adjustment
Time resolving 10 ms resolving time of the calibrator
Accuracy rpm adjustment 0.1 rpm the accuracy of the rotational speed adjustment
Rpm resolution 0.05 rpm resolution of the rotational speed
Software available in English
Software available in English
Software available in German
Software available in German
Software available in Dutch
Software available in Dutch
Software available in Japanese
Software available in Japanese
USB connector
connection via USB possible
RS232 in connector
connection via RS232
Cable length 3000 mm 118.1 inch length of cable
Product length (cm) 52 cm 20.5 inch length of product in cm
Product width (cm) 32 cm 12.6 inch width of the product in cm
Product height 52 cm 20.5 inch height of product
Product weight 29 kg 63.9 lbs the weight of the product
100 / 230V AC 50/60 Hz
5,5 / 8,5 A - at 110 V: 500 Watt
Phases 1 phases
Integrated emergency stop
emergency stop fully integrated
Maximum operational temperature 35 °C maximum temperature at which the device will work within specification
Minimum operational temperature 14 °C minimum temperature at which the device will work within specification
Maximum operational air pressure 106 kPa maximum air pressure as from which the product will be operating within specification
Minimum operational air pressure 80 kPa minimum airpressure as from which the product will be operating within specification
Maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
Minimum operational non-condensing humidity 30 % minimum non-condensing humidity at which the product will operate within specification
Maximum storage & transport temperature 60 °C maximum temperature the product may be stored or transported at
Minimum storage & transport temperature -20 °C minimum temperature the product may be stored and transported at
Maximum storage & transport air pressure 106 kPa maximum air pressure the product may be stored and transported at
Minimum air pressure storage & transport 50 kPa minimum air pressure the product may be stored or transported at
Max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
Min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at
Internal RAM 4 MB minimum PC internal memory
Minimum Free Hard Disk space 25 GB software and storage size requirement
Number of free USB ports 2 for connection purposes
Suitable for all brands
Calibrator can be used for ergometers of all brands
Suitable for high power ergometers
Calibrator can be used for ergometers with a max. worload of >1000 W
Microsoft Windows 10
compatible with Microsoft Windows 10
PC software included
software needed for operation included
*Specifications are subject to change without notice.

FAQ

A static calibration is used for some ergometers to check the assumed linear relationship between 2 workload points with use of weights. This type of calibration is not accurate because the driving gear is not taken into account and the relationship is not totally linear at higher and lower workloads. Historically mechanical ergometers are calibrated by this method the accuracy is shifting a lot between tests because the belt-length (mechanical braking part) is influenced by heatening. Static calibration is not fulfilling any relevant norm. Dynamic calibration is performed by a service engineer with a calibrator. The ergometer is calibrated at the axis in the total workload and rpm range (instead of 2 points without any movement of the driving gear). The data can be compared with the initial calibration report from the factory to check drifting in time. A calibration report is printed for the customer and stored by the service engineer. Dynamic calibration performed with a Lode calibrator is accurate and fulfills all relevant norms and certifications.

Part number

  • 919950

Certificates

ISO 13485:2003 Certificate
CE Certificate Stress Test and Force Measurement Devices
ISO 9001:2008 Certificate

Manuals

Manual Calibrator ULTRA / Versa - English

Brochures

Brochure Portable Calibrator Ultra 230V English
pdf
Brochure Calibration English
pdf
Brochure Portable Calibrator Ultra 230V German
pdf
Brochure Calibration German
pdf

Posters

Poster Portable Calibrator Ultra 230V English
Poster Portable Calibrator Ultra 230V German

Service

Part number

  • 919950