Calibrator 2000

Dynamic calibration on site

The Calibrator 2000 is a portable calibration station. The calibration station is controlled by a PC or laptop. With this station it is possible to control or calibrate all existing ergometers. The Lode Calibrator 2000 is mounted on the axis of the ergometer. This system is approved by PTB (German independent institute) in Berlin, and is used by calibration institutes in Germany since 1993. The accuracy is according to the LMKM guideline of PTB.  Calibrations can be done up to 1000 watt. Due to the possibilities you create when using a normal PC to calibrate the calibrator you can print a calibration report for your customer and/or create your own database of calibration data.

Specifications

Maximum rotational speed 130 rpm calibrator maximum rotations
Rotation direction clockwise
looking at the outgoing axis
Rotation direction anti-clockwise
looking at the outgoing axis
Maximum motor torque 73 Nm the maximum torque the motor can deliver
Maximum sensor torque 100 Nm the maximum torque the sensor can measure
Warming up time 5 min the time to bring the product on operational temperature
Approved power range (maximum) 500 W power range for which use is approved
Approved power range (minimum) 0 W power range for which use is approved
Power range at maximum rpm (maximum) 1000 W operational power range
Power range at maximum rpm (minimum) 0 W operational power range
Crank adapter included
to connect crank to calibrator
Power accuracy error > 100 W 2 % accuracy of power application
Power accuracy error up to 100W 1.8 W accuracy of power application
Torque resolution 0.04 Nm resolution of the torque adjustment
Time resolving 10 ms resolving time of the calibrator
Accuracy rpm adjustment 0.2 rpm the accuracy of the rotational speed adjustment
Rpm resolution 0.1 rpm resolution of the rotational speed
RS232 in connector
connection via RS232
RS232 out connector
connection via RS232
Product length (cm) 64 cm 25.2 inch length of product in cm
Product width (cm) 20 cm 7.9 inch width of the product in cm
Product height 45 cm 17.7 inch height of product
Product weight 34 kg 75 lbs the weight of the product
PTB approval possible
approval of PTB possible
Minimum operational temperature 14 °C minimum temperature at which the device will work within specification
Maximum operational temperature 40 °C maximum temperature at which the device will work within specification
Minimum operational non-condensing humidity 20 % minimum non-condensing humidity at which the product will operate within specification
Maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
Minimum storage & transport temperature 0 °C minimum temperature the product may be stored and transported at
Maximum storage & transport temperature 60 °C maximum temperature the product may be stored or transported at
Max. humidity storage & transport 90 % max. non-condensing humidity that the product can be stored or transported at
PC software included
software needed for operation included
*Specifications are subject to change without notice.

FAQ

A static calibration is used for some ergometers to check the assumed linear relationship between 2 workload points with use of weights. This type of calibration is not accurate because the driving gear is not taken into account and the relationship is not totally linear at higher and lower workloads. Historically mechanical ergometers are calibrated by this method the accuracy is shifting a lot between tests because the belt-length (mechanical braking part) is influenced by heatening. Static calibration is not fulfilling any relevant norm. Dynamic calibration is performed by a service engineer with a calibrator. The ergometer is calibrated at the axis in the total workload and rpm range (instead of 2 points without any movement of the driving gear). The data can be compared with the initial calibration report from the factory to check drifting in time. A calibration report is printed for the customer and stored by the service engineer. Dynamic calibration performed with a Lode calibrator is accurate and fulfills all relevant norms and certifications.
Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!

Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.

Part number

  • 919900

Certificates

ISO 13485: 2016 Certificate
CE Certificate Stress Test and Force Measurement Devices
ISO 9001:2015 Certificate

Manuals

Installation instruction WinCalibrator 2000
Manual Calibrator 2000

Brochures

Brochure Calibrator 2000 English
pdf
Brochure Calibrator 2000 German
pdf
Brochure Calibrator 2000 Spanish
pdf

Posters

Poster Calibrator 2000 English
Poster Calibrator 2000 German
Poster Calibrator 2000 Spanish

Service

Part number

  • 919900