Maximum speed | 20 km/h | 12.4 mph | maximum speed of the treadmill |
Minimum operational speed | 0.5 km/h | 0.3 mph | minimum speed of the treadmill |
Positive elevation | 25 % | maximum positive angle as a percentage | |
Elevation adjustment steps | 0.5 % | the size of the steps you can adjust the elevation | |
Optional negative elevation | -10 % | mimimum negative angle percentage that can be reached with the optional accessory |
Speed accuracy | 5 % | accuracy of speed | |
Accuracy inclination | 0,5 % | Accuray of the inclination |
Allowed user weight | 225 kg | 496 lbs | maximum patient weight |
USB connector | connection via USB possible | ||
RS232 in connector | connection via RS232 |
Screen resolution | 320x240 pixels | Screen resolution | |
Walking surface length | 170 cm | 66.9 inch | length of the walking surface |
Walking surface width | 60 cm | 23.6 inch | width of the walking surface |
Step up height | 17 cm | 6.7 inch | height to step up the treadmill |
Product length (cm) | 235 cm | 92.5 inch | length of product in cm |
Product width (cm) | 90 cm | 35.4 inch | width of the product in cm |
Product height | 130 cm | 51.2 inch | height of product |
Product weight | 200 kg | 440.9 lbs | the weight of the product |
Power cord length | 250 cm | 98.4 inch | length of powercord including plugs |
Power cord IEC 60320 C19 with CEE 7/7 plug | European power cord and connector standard supplied with product | ||
Power cord NEMA | NEMA power cord and connector | ||
Maximum rated power input | 2500 VA | power input | |
115 V AC 50/60 Hz (2 phases) | when <230V, the treadmill should be connected between two phases | ||
230 V AC 50/60 Hz | operational power | ||
Maximum motor power | 1.8 kW | the maximum power the motor will consume |
IEC 60601-1:2005 | the product is IEC 60601-1 3rd edition compliant | ||
ISO 13485:2016 compliant | Lode fulfils ISO 13485:2016 requirements | ||
ISO 9001:2015 compliant | Lode fulfills ISO 9001: 2015 requirements | ||
Standard emergency lanyard | an emergency stop with a magnetic lanyard is present |
CE class Im according to MDD93/42/EEC | CE certified | ||
CE class of product with optional SpO2 | IIa | CE class of product with optional SpO2 | |
CE class of product with optional BPM | IIa | CE class of product with optional Blood Pressure Measurement | |
CB according to IECEE CB | CB certified |
Maximum operational temperature | 40 °C | maximum temperature at which the device will work within specification | |
Minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification | |
Maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification | |
Minimum operational air pressure | 70 kPa | minimum airpressure as from which the product will be operating within specification | |
Maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification | |
Minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification | |
Maximum storage & transport temperature | 70 °C | maximum temperature the product may be stored or transported at | |
Minimum storage & transport temperature | -25 °C | minimum temperature the product may be stored and transported at | |
Maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at | |
Minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at | |
Max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at | |
Min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at |